PCQI Insights
PCQI Recordkeeping and Food Safety Plan Documentation Integrity
Quick answer: food safety plan documentation integrity means records that are accurate, indelible, legible, created at the time of the activity and easy to retrieve. 21 CFR 117.305 sets these rules, and a PCQI must review key records. For Walmart suppliers, sound records show that controls really ran.
Food safety plan documentation integrity matters because good work is hard to prove without good records. Even an effective operation can struggle when records are incomplete or cannot be found. That matters during audits, investigations and food safety plan review.
Walmart may have its own supplier programs and expectations. These depend on the product, the facility, the commercial relationship and current law. So confirm any Walmart-specific requirement with the relevant Walmart contact before you treat a practice here as a Walmart rule. For how PCQI record review works in practice, see our guide to PCQI food safety record review.
Five Steps to Protect Food Safety Plan Documentation Integrity
1. Inventory the required food safety records
List the records that apply to your facility. 21 CFR 117.190 covers monitoring, corrective actions, verification (including validation, calibration, testing, records review and reanalysis), the supply-chain program and PCQI training. The written plan itself is also a record under 117.126(c).
Take obligations from the rule that applies, not from a generic list. First, confirm that Part 117 Subpart C applies. Some facilities are exempt from subparts C and G, such as qualified facilities under 21 CFR 117.5(a) or dietary supplement operations that comply with Part 111 under 117.5(e). For them, these PCQI duties may not apply.
2. Design complete and attributable forms
21 CFR 117.305 says records must contain actual values and observations. They must also be created at the time of the activity and be detailed enough to show the history of the work.
So each form should capture the facility, the date and, when appropriate, the time, the signature or initials of the person doing the work, and, where appropriate, the product and lot code. A checked box alone is not always enough to show that a control ran as required.
3. Protect authorized review and approval
Identify who performs the required record review under 21 CFR 117.165(a)(4) and how that approval is shown. The review must be done by, or under the oversight of, a PCQI.
Do not treat a typed name or initials alone as verified authorization without supporting controls. In addition, 21 CFR 117.310 requires the owner, operator or agent in charge to sign and date the food safety plan on completion and on any change.
Corrections, Electronic Records and Retrieval
4. Control corrections and electronic records
Records must be accurate, indelible and legible. Therefore, define a legible correction method, access permissions, backups, version history and retention.
Never silently overwrite original records, and keep obsolete forms away from points of use. Under 117.305(g), electronic records kept only to meet Part 117 are exempt from Part 11. Records also required by other rules stay subject to Part 11. A records platform such as SystemsBuilder can hold version history and approvals, but it does not replace the required PCQI review.
5. Test inspection retrieval
Practice finding sample records, their corrective actions and the linked plan provisions. Under 21 CFR 117.315, records must be kept for at least 2 years after they were prepared. The food safety plan must stay onsite, and offsite records must be retrievable within 24 hours of a request for official review.
Also, 117.320 requires records to be made promptly available to FDA on request. Handle any separate Walmart record requests on their own terms, as confirmed with Walmart.
Food Safety Plan Documentation Integrity Checklist
✓ Inventory the required food safety records for your facility.
✓ Design complete and attributable forms with actual values, dates and lot codes.
✓ Protect authorized PCQI review and plan sign-off.
✓ Control corrections, electronic records, backups and obsolete forms.
✓ Test retrieval against the 2-year retention and 24-hour offsite rules.
✓ Verify the applicable Walmart supplier program and all relevant product and facility requirements.
✓ Assign owners for documentation, follow-up actions and periodic review.
Frequently Asked Questions
How long must food safety plan records be kept?
At least 2 years after the date they were prepared, under 21 CFR 117.315(a)(1). Records about the general adequacy of equipment or processes, such as validation studies, are kept at least 2 years after their use ends.
Can we store records offsite or electronically?
Yes, except the food safety plan, which must remain onsite. Offsite records must be retrievable within 24 hours. Electronic records count as onsite if they are accessible from an onsite location.
Is a checked box enough evidence?
Not always. Part 117 records must contain actual values and observations from monitoring and, as appropriate, verification.
Official References
21 CFR Part 117 (eCFR)
FDA: FSMA Final Rule for Preventive Controls for Human Food
Walmart: Supplier Requirements
PCQI Insights
Related Reading
Records Compliance Management Program
Set up record forms, retention and retrieval that hold up to review.
Learn more →
PCQI Food Safety Record Review for Walmart Suppliers
Review deadlines and what a reviewer must confirm under 21 CFR 117.165(a)(4).
Read article →
PCQI Record Review and Food Safety Plan Maintenance
A manufacturer’s guide to record review, reanalysis and plan upkeep.
Read article →
Need Help Managing Your PCQI Responsibilities?
Talk with our team about form design, record integrity, retrieval and open documentation gaps.
Independent educational content. PCQI Services is not affiliated with or endorsed by Walmart Inc. or the U.S. Food and Drug Administration (FDA). Walmart-specific supplier requirements must be confirmed directly with the relevant Walmart contact. Meeting FDA requirements or working with PCQI Services does not guarantee supplier acceptance. Regulatory applicability depends on the product, facility, activity and current law. Read our terms.